As a fire protection system service company, we’ve performed thousands of fire alarm inspections, testing, and maintenance services. Our technicians usually spot the same fire alarm deficiencies when they service a new customer’s fire alarm system. These common problems involve pull stations, smoke detectors, and fire alarm batteries. Once you know about these fire alarm deficiencies, you can identify them and take the following steps to prevent these top 3 deficiencies.

Fire Alarm Pull Stations

The two most commonly found fire alarm pull station code violations include obstruction and incorrect installation height. Facilities usually block pull stations with furniture, plants, boxes, inventory etc. Pull stations must be easy to spot, access, and remain unobstructed at all times. NFPA 72, 2013 requires a semiannual visual inspection. But you can easily prevent this fire alarm pull station deficiency by training your facility’s team to regularly check up on pull stations. Additionally, make sure your manual fire alarm boxes locations are no less than 42in. and no more than 48in. from the floor. You’ll only have to check on this once unless you have new pull stations installed in your facility.

Smoke Detectors

Smoke detectors produce false alarms when dust or bugs clog up their chamber. Double check your service contract and make sure your fire alarm contractor performs smoke detector sensitivity testing every 2 years. This test requires technicians to clean out the smoke detector’s chamber and ensure it’s free from any dust or particles. If construction or any event creates a dusty environment, temporarily cover smoke detectors to prevent particle build-up. This ensures your detectors remain fully operational in between smoke detector sensitivity testing.

Fire Alarm Batteries

Fire alarm panel batteries are a secondary source of power that keeps your system running even if the primary source fails. A low battery can occur at any time. The batteries life span depends on how often it’s used as the primary power source. According to NFPA 72, 2013 lead acid-type batteries require an annual replacement. Additionally, replace batteries according to the manufacture’s specifications. To prevent low battery fire alarm deficiencies, check on your fire alarm panel. Most panels will indicate whether one of your fire alarm batteries is running low.

As a facility manager, you need to keep all the systems in your facility running properly. Unlike some systems in facilities, facility maintenance can take the initiative to prevent fire alarm deficiencies from occurring. You only need to take a few preventative steps to eliminate the most common fire alarm deficiencies.